UPS 7400
UPS 7400
PWM Based IGBT Inverter
The rectifier provides up to 0.99 Input Power Factor (PF), up to 3% of Input Current Total Harmonic Distortion (THDi) with
Optional configurations of Harmonic filters and the widest input voltage window
and frequency tolerances.
Advanced inverter control technology provides the highest output power quality,
ensuring very low output voltage THD and superior waveform to protect connected
loads.
It operates under a wide variety of conditions, handling 100% non-linear loads with
3:1 crest factor, as well as 100% unbalanced loading.
The inverter control enables 7400M to be suitable for the widest ranges of loads
required by the market; delivering full active power rated kW up to 0.9 leading PF loads.
n
n
n
n
Input Isolation Transformer
- Compatible with Liebert AF, the Active Harmonic Filter
- Wide range of solutions specially designed for handling
current harmonic on bypass at different stages
- Available for rectifier and / or bypass supply
Protection Degree (IP) For 7400M Enclosure
- To address stressed environmental conditions, UPS with
higher than IP20 degree of protection can be made
available for most of the kVA ratings of 7400M
DC Ground Fault Indication
- This provides indication of occurrence of battery ground
fault problems
i-Enersave Module
- Purpose of this logic is to optimally load each UPS system
in a multi UPS parallel system so that each UPS works in its
most efficient band of operation while total installation
being subjected partial load. This logic keeps minimum number
of UPS system in Operation as per load demand.
The choice of redundancy level is settable in the logic
to have high up-time depending on criticality index of
load, it has wide use in industries where load pattern is
Highly dynamic.
- Auto Sleep and Auto sequencing options available with this logic
Ensures no UPS System is spared from regular health check up, if
Prolonged conditions persist. Thus enhanced efficiency of overall
System reduces Energy cost and increased customer profitability.
This tacitly reduce consumption of natural resources,
Combustion of fossil fuel, hence reduction in green house gas
Emission and carbon footprint.
Power Walk-in for 1+N System
- The module power walk-in is standard. This option can be
For the module restart delay after the mains return. This is
Very useful for applications with motor generator at the
Input
LBS
- This ensures the synchronization of outputs of two
Independent UPS systems to form Dual Bus Architecture
For High availability of Critical Bus
Liebert LTS, Static Transfer Switch
- This allows critical load to be transferred between two
independent, synchronized AC power sources without any
risk of load disturbances
- This allows automatic transfer of load between the two
sources
TVSS
- This is a Transient Voltage Surge Suppressor
- This offers protection from damaging transients and
electrical line noises
- This is normally connected at the I/P and O/P path of
7400M as an optional item